Need help? Call us 020 8440 5350

Email us on info@saveonkit.com

MAHA MET 6.3 Emissions Tester Combitester Petrol Opacimeter DiTest Speed 2000

£2,850.00
£2,375.00 ex VAT

Pre-owned


Product overview

Electrochemical detection: O2
Measurement range: O2: 0-25 % Vol./0.01
Measuring range, particle concentration: 1-1100 mg/m³
Measurable gases: HC, CO, CO2, O2
Measurement principle: absorbance measurement
Measuring range, turbidity: 0-100 %
MPN: MAHA MET 6.3, AVL DITEST SPEED 2000
Power supply: 110-230V 50/60 Hz
Measurement range: CO: 0-15% Vol./0.01
Lambda (calculated): 0-9.99/0.01
Weight: approx. 10.0 kg
Operating pressure: 0 (OIML)
Brand: MAHA
Type: Exhaust Emission Tester
Dimensions (L x W x H): 406 x 225 x 160 mm
Measuring range, absorption coefficient: 0-9.99 m-1
Resolution, absorption coefficient: 0.01 m-1
Resolution, particle concentration: 1 mg/m³
Heat-up time for measuring cell: 150 s
Measurement principle: infrared spectrometry: HC, CO, CO2
Measurement range: HC: 0-30000 ppm/1
Measurement range: CO2: 0-20 % Vol./0.01

MAHA MET 6.3 Emissions Tester Combitester Petrol Opacimeter DiTest Speed 2000

Model: MAHA MET 6.3
Model: AVLDiTest Speed 2000

In good condition and full working order 

FUNCTIONS AT A GLANCE:
Speed measurement for stationary and dynamic speed curves
For petrol and diesel engines(best coverage)
No setting of cylinder numbers required
Easy mounting thanks to integrated permanent magnets
Automatic self-calibration and function monitoring
Unique and direct signal pickup
Future-proof due to independence of electrical motor signals
Compatible with every emission tester

MORE DETAILS AT A GLANCE:
Unique and direct signal pick up via structure-borne sound
No setting of cylinder numbers required
Easy mounting thanks to integrated permanent magnets
Universal connection to any emission tester possible
For stationary and dynamic speed measurement
For petrol and diesel engines with the highest coverage rate
Automatic self-calibration and function monitoring
Standard for passenger cars, commercial vehicles and motorcycle 2-/4-stroke
Mode switch integrated in device
USB 2.0 interface integrated
Data transfer and software update via USB
Easy
The combination sensor is installed with a magnetic foot to the vehicle
Fast
Disassembly, manual calibration and laborious settings are not required
Universal
The AVL DITEST SPEED 2000 can be used on passenger cars, commercial vehicles and motorcycles, no matter how many cylinders the engine has.

Technical Spec

More Info:
MAHA MET 6.3 Exhaust Gas Combitester
Combination of MET 6.1 (gasoline/gas) and MET 6.2 (opacimeter) in a compact housing
Measurement of HC, CO, CO2, O2, NOX(option), K value,turbidity, particle mass concentration
Available with two-point calibration (MET6.3/2)
Description:
Emission tester stands out due to limited weight and compact design
Short warm-up time, quick measurement readiness
Accurate analysis of gas components HC, CO, CO2, O2 with lambda value calculation
Time-saving and easy testing/diagnosis of opacity/particle concentration using the partial flow method with free acceleration or engine under load
Intuitive operation, clear structure in emissions testing process as set out in current guidelines 5 enable minimum cycle times
The MAHA VCI makes EOBD analysis easy
Innovative condensate separation thanks to active water separator
Easy to maintain thanks to optimum accessibility
Future-proof with the latest technology
All measurement values HC, CO, CO2, O2, K-value, turbidity, particle concentration can be displayed simultaneously
Petrol Tester Module Description:
Partial flow emission tester with display unit (basic device) for analysis of gas components HC, CO, CO2 and O2 with lambda value calculation
Emission testing of CNG, LPG and petrol engines possible
MET 6.3 Technical Data:
Power supply: 110-230V 50/60 Hz
On-board voltage connection: 10-30 V, DC
Dimensions (L x W x H): 406 x 225 x 160 mm
Weight: approx. 10.0 kg

MET 6.3 Gas Analyser Unit Technical Data:
Measurable gases: HC, CO, CO2, O2
Measurement principle: infrared spectrometry: HC, CO, CO2
Electrochemical detection: O2
Operating pressure: 750-1100 hPa
Accuracy class: 0 (OIML)
Measurement range / measured value resolution (max.):
CO: 0-15% Vol./0.01
CO2: 0-20 % Vol./0.01
HC: 0-30000 ppm/1
O2: 0-25 % Vol./0.01
Lambda (calculated): 0-9.99/0.01

Opacity/Particle Concentration Unit:
Measurement principle: absorbance measurement
Heat-up time for measuring cell: 150 s
Measuring range, turbidity: 0-100 %
Measuring range, absorption coefficient: 0-9.99 m-1
Resolution, absorption coefficient: 0.01 m-1
Measuring range, particle concentration: 1-1100 mg/m³
Resolution, particle concentration: 1 mg/m³

What's Included

1x MAHA MET 6.3 Emissions Tester Combitester Petrol Opacimeter
1x Power Supply
1x Mobility Kit Case
1x Inductive RPM Probe
1x Exhaust Probe
1x AVL DiTest Speed 2000
1x AVL DiSpeed Ultrasonic Speed sensor BO2338
1x 6-Pin to 5-Pin 5m Cable
1x 6-Pin 60cm Cable
1x Ethernet Cable

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Klarna
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

More about this product

Delivery Information

We primarily uses FedEx and DHL to ship all orders. The courier used will depend on the destination of the shipment, volumetric weight and service level paid for. We may use alternative couriers for specialist orders such as pallet network deliveries. We aim to have all UK orders delivered within two business days of a completed order. International orders are dependent on location. Please see here for further delivery information.

Returns Policy

We want all our customers to be happy with their purchases. We offer a 14-day return policy and a 6-month warranty as standard on all our products. Extended warranties are available upon request on most products. If you do experience any issues, please just get in contact with us and we shall do what we can do remedy the situation.

Please see here for our full returns policy.

Warranty Information

We give a 6 month warranty on all products as standard. We aim to provide great products and a great service first and foremost. if you have any issues at all, please do get in touch and we will do what we can to help out! Please see here for full details.

Check out our FAQ's

Need more information on how we work at SaveOnKit? See our FAQ's to find out more about shipping, product warranties and international orders.

MAHA

MAHA MET 6.3 Emissions Tester Combitester Petrol Opacimeter DiTest Speed 2000

£2,850.00
£2,375.00 ex VAT

Electrochemical detection: O2
Measurement range: O2: 0-25 % Vol./0.01
Measuring range, particle concentration: 1-1100 mg/m³
Measurable gases: HC, CO, CO2, O2
Measurement principle: absorbance measurement
Measuring range, turbidity: 0-100 %
MPN: MAHA MET 6.3, AVL DITEST SPEED 2000
Power supply: 110-230V 50/60 Hz
Measurement range: CO: 0-15% Vol./0.01
Lambda (calculated): 0-9.99/0.01
Weight: approx. 10.0 kg
Operating pressure: 0 (OIML)
Brand: MAHA
Type: Exhaust Emission Tester
Dimensions (L x W x H): 406 x 225 x 160 mm
Measuring range, absorption coefficient: 0-9.99 m-1
Resolution, absorption coefficient: 0.01 m-1
Resolution, particle concentration: 1 mg/m³
Heat-up time for measuring cell: 150 s
Measurement principle: infrared spectrometry: HC, CO, CO2
Measurement range: HC: 0-30000 ppm/1
Measurement range: CO2: 0-20 % Vol./0.01

MAHA MET 6.3 Emissions Tester Combitester Petrol Opacimeter DiTest Speed 2000

Model: MAHA MET 6.3
Model: AVLDiTest Speed 2000

In good condition and full working order 

FUNCTIONS AT A GLANCE:
Speed measurement for stationary and dynamic speed curves
For petrol and diesel engines(best coverage)
No setting of cylinder numbers required
Easy mounting thanks to integrated permanent magnets
Automatic self-calibration and function monitoring
Unique and direct signal pickup
Future-proof due to independence of electrical motor signals
Compatible with every emission tester

MORE DETAILS AT A GLANCE:
Unique and direct signal pick up via structure-borne sound
No setting of cylinder numbers required
Easy mounting thanks to integrated permanent magnets
Universal connection to any emission tester possible
For stationary and dynamic speed measurement
For petrol and diesel engines with the highest coverage rate
Automatic self-calibration and function monitoring
Standard for passenger cars, commercial vehicles and motorcycle 2-/4-stroke
Mode switch integrated in device
USB 2.0 interface integrated
Data transfer and software update via USB
Easy
The combination sensor is installed with a magnetic foot to the vehicle
Fast
Disassembly, manual calibration and laborious settings are not required
Universal
The AVL DITEST SPEED 2000 can be used on passenger cars, commercial vehicles and motorcycles, no matter how many cylinders the engine has.

View product